ALPHA-VISION® History: AV Main |
| CardId | Description |
|---|---|
| 6886 |
SoftPlc7AciConnect, AlphaVision installer packets: XceedZip.dll was missing in SoftPlc7 installer and libxml2.dll was included
but not needed.
As aci.dll needs XceedZip.dll to read the *.do files this caused an error (wrong version number in binary file) when using SoftPlc7 and AciConnect without AlphaVision. |
| 6932 | AvDiag: tabs in dialog are optically scrambled and not translated to german |
| CardId | Description |
|---|---|
| 6290 |
AvDiag: new features
- new tab logfiles: enable/disable logfiles; define size - refresh button global - zip logfiles + DIS/DO-Files + Ini-Files + Cfg-Files |
| CardId | Description |
|---|---|
| 5975 | In a program it is not possible to delete files and then the empty folder (_rmdir), if it has been created by AbCopyFiles2Dir |
| 5763 | German 10.x versions of AV programs do not start but issue an error that some Microsoft runtime dll was not found. This happens even if the correct version of the dll has been installed with the vc_redist installer included in the AV installer. |
| 6164 | AV-Installers: When installing a packet with a different language the user is asked if he wants to install the wrong language or not but there is no cancel button and the wrong language is always installed.. |
| CardId | Description |
|---|---|
| 5964 |
[CopyOf:5759]Licence-Check: When using software keys: if the PC clock is set to a time before the licence installation (30
day key) the licence check fails after some time and vision is closed with the following message:
The system time has been set to a value before the beginning of the licenced period (30 days licence), possibly to bypass licence restrictions. |
| CardId | Description |
|---|---|
| 5759 |
Licence-Check: When using software keys: if the PC clock is set to a time before the licence installation (30 day key) the
licence check fails after some time and vision is closed with the following message:
The system time has been set to a value before the beginning of the licenced period (30 days licence), possibly to bypass licence restrictions. |
| CardId | Description |
|---|---|
| 5727 | AV-installers do not run a second time with the same version e.g. to do a repair install or to install components not selected in the first run |
| CardId | Description |
|---|---|
| 5710 |
AvDiag - new tool which combines AbGetLicInfo and AbVersionInfo into a more user-friendly diagnosis tool and to correct
incompatibilities with AV-10.x versions.
Additional features: * save all info in one file * completely dialog-based * search directories in PATH only upon user request |
| CardId | Description |
|---|---|
| 3443 | WIBU-Key Runtime-Installer in den AV-Installer einbinden. |
| CardId | Description |
|---|---|
| 5642 | AbHelp: wrong colours used in alpha-bit logo and headlines |
| 5655 |
AlphaVision binaries specify the wrong version of MSVC runtime libraries and MFC libraries in their embedded manifest, AV
installers install the correspondingly wrong library versions. This may cause errors when the needed versions of the libraries
are not installed on a PC.
|
| CardId | Description |
|---|---|
| 5604 | Licence-Check: if the *.DIS or *.DO file of a AV-project was compiled with a demo version of AV then the runtime using such a file should also run as a demo version even if it has a valid licence. |
| 5084 | AbHelp: Separate languages into different directories |
| 5441 | All AV applications and tools have new icons matching the new alpha-bit logo. |
| 4893 | Convert AV to Visual Studio 2008 |
| CardId | Description |
|---|---|
| 5197 |
AbvEditor crashes when a Figure is saved which contains calls to functions where the last parameter is left out without
leaving a trailing comma in the parameter list.
----- Workaround: Leave a trailing comma in the parameter list of jobs where parameters are missing at the end. |
| 5198 | AbvEditor: When saving a figure, formal parameters are not generated from the MouseOver action. |
| 5307 | Licence-Check: Functions from Plugin-DLLs which are loaded after program start are not checked for test version and no warning is issued. |
| CardId | Description |
|---|---|
| 5070 | AbHelp: Tree-View navigation does not work |
| CardId | Description |
|---|---|
| 4716 |
Licence Check: On some hardware (Siemens SIMATIC Field PG) when no Ethernet cable is connected to the OS and the user starts
a program (PMU, AbvEditor, Zip2Dbf, MdConv) that checks its licence under Windows XP the program crashes.
----- Workaround: Connect the OS to an Ethernet switch |